Electrical Test Meters

Fluke 87V TRMS Industrial Multimeter

£563.00

The Fluke 87V TRMS Industrial Multimeter provides the resolution and accuracy needed to troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment. It is designed to perform in loud, high-energy, and high-altitude environments. A selectable low-pass filter and special input shielding allow accurate measurements on noisy VFD outputs, both at the drive and at the motor terminals, reducing the effect of high-frequency, high-energy noise from large systems.

Fluke 87V TRMS Industrial Multimeter

The 87V takes the guesswork out of drive system troubleshooting. Enable the low-pass filter to stabilise voltage and frequency readings on VFD outputs, and rely on the instrument’s shielding to block high-frequency noise that can distort measurements around large drives. Fast Peak Min/Max captures events down to 250µs, while the analogue bar graph and bright backlight make changing signals easy to follow on site. Rated CAT IV 600V, CAT III 1000V, the 87V is built for demanding field conditions and industrial panels.

Typical applications

•  Troubleshooting VFD-driven motors and controllers
•  Plant automation and process control diagnostics
•  Power distribution, UPS and switchboard work
•  General electromechanical maintenance

Why this model

•  True-RMS accuracy for non-linear loads
•  Selectable low-pass filter for VFD voltage and frequency at drive or motor terminals
•  Special input shielding to reduce high-frequency, high-energy noise
•  Peak Min/Max capture to 250µs for transients and intermittents
•  High basic DC accuracy and stable readings in challenging environments
•  Safety rated CAT IV 600V, CAT III 1000V for industrial use

Spec summary

•  DC voltage to 1000V, basic accuracy ±(0.05%+1)
•  AC voltage to 1000V TRMS, 20kHz bandwidth with LPF
•  DC/AC current to 10A continuous, 20A for 30s max
•  Resistance, conductance, capacitance, frequency, duty cycle
•  Temperature measurement with a Type-K probe
•  Peak Min/Max capture 250µs
•  Safety CAT IV 600V, CAT III 1000V
•  Operating temperature −20°C to +55°C

Fluke 87V FAQs

Can it measure VFD outputs reliably.
Yes, use the low-pass filter to obtain stable voltage and frequency readings at the drive or at the motor terminals.

What transients can it capture.
Peak Min/Max records events as short as 250µs, useful for nuisance trip diagnosis.

What are the safety ratings.
CAT IV 600V and CAT III 1000V for industrial environments.

Does it measure temperature.
Yes, when used with a compatible Type-K thermocouple probe.

What current ranges are available.
Up to 10A continuous, or 20A for 30s max on the amps input.